What was found
DURING OP 16 MAINT CHECK, FOUND CORROSION ON FLOOR SUPPORT AT STA 200. NUMBER 1 FLOOR TRACK TO MEMBRANE AREA, LBL 50. CORROSION WAS REMOVED PER SRM 6-80-01, PAGE 1 AND REPLACED FLOOR SUPPORT PER SPM 6-70-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING OP 16 MAINT CHECK, FOUND CORROSION ON FLOOR SUPPORT AT STA 200. NUMBER 1 FLOOR TRACK TO MEMBRANE AREA, LBL 50. CORROSION WAS REMOVED PER SRM 6-80-01, PAGE 1 AND REPLACED FLOOR SUPPORT PER SPM 6-70-01.