What was found
DURING OP 16 MAINT CHECK, FOUND CORROSION ON FLOOR SUPPORT AT STA 200, BETWEEN NUMBER 1 AND 2 SEAT TRACKS. REPLACED FLOOR SUPPORT PER STD PROCESSES MANUAL 6-70-01, PAGE 3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING OP 16 MAINT CHECK, FOUND CORROSION ON FLOOR SUPPORT AT STA 200, BETWEEN NUMBER 1 AND 2 SEAT TRACKS. REPLACED FLOOR SUPPORT PER STD PROCESSES MANUAL 6-70-01, PAGE 3.