What was found
DURING OP 16 MAINT CHECK, FOUND STA 200 FLOORBEAM CAP CORRODED JUST OUTBOARD OF NUMBER 4 CHAIR TRACK. REPAIRED FLOORBEAM PER SRM 53-05, PAGE 31.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING OP 16 MAINT CHECK, FOUND STA 200 FLOORBEAM CAP CORRODED JUST OUTBOARD OF NUMBER 4 CHAIR TRACK. REPAIRED FLOORBEAM PER SRM 53-05, PAGE 31.