What was found
DURING OP 16 MAINT CHECK, INTERCOSTAL WAS CRACKED APPROXIMATELY .25 INCH IN BEND RADIUS AT FWD LOWER CORNER JUST AFT OF STA 69.5, RBL 12.5. MANUFACTURED NEW INTERCOSTAL PER DRAWING PO9530268. PRIMED AND INSTALLED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING OP 16 MAINT CHECK, INTERCOSTAL WAS CRACKED APPROXIMATELY .25 INCH IN BEND RADIUS AT FWD LOWER CORNER JUST AFT OF STA 69.5, RBL 12.5. MANUFACTURED NEW INTERCOSTAL PER DRAWING PO9530268. PRIMED AND INSTALLED.