What was found
DURING OP 16 MAINT CHECK, FOUND CENTER FRAME (9911505-7) CRACKED THROUGH RIVET AT OTBD END OF STA 83.5, X=-10, LT SIDE UPPER FLANGE JUST AFT OF RADIUS REF SPM 53-03 PAGE 143. INSTALLED NEW FRAME PER SPM 6-70-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING OP 16 MAINT CHECK, FOUND CENTER FRAME (9911505-7) CRACKED THROUGH RIVET AT OTBD END OF STA 83.5, X=-10, LT SIDE UPPER FLANGE JUST AFT OF RADIUS REF SPM 53-03 PAGE 143. INSTALLED NEW FRAME PER SPM 6-70-01.