What was found
DURING OP 16 MAINT CHECK, FOUND CENTER FRAME (9911505-7) CRACKED .75 INCH LONG IN OTBD END STA 83.5, X=-10 ON RT SIDE. REF SRM 53-03, PAGE 143 IN RADIUS. INSTALLED NEW FRAME PER SPM 6-70-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING OP 16 MAINT CHECK, FOUND CENTER FRAME (9911505-7) CRACKED .75 INCH LONG IN OTBD END STA 83.5, X=-10 ON RT SIDE. REF SRM 53-03, PAGE 143 IN RADIUS. INSTALLED NEW FRAME PER SPM 6-70-01.