What was found
DURING OP 16 MAINT CHECK, FOUND CABIN STRINGER 2L CRACKED AT FORMER STA 200. REPLACED CRACKED SECTIONS AND INSTALLED SPLICE PER SRM 53-02, PAGE 48 FIG 18, STA 188 TO 229.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING OP 16 MAINT CHECK, FOUND CABIN STRINGER 2L CRACKED AT FORMER STA 200. REPLACED CRACKED SECTIONS AND INSTALLED SPLICE PER SRM 53-02, PAGE 48 FIG 18, STA 188 TO 229.