What was found
DURING OP 16 MAINT CHECK, CHAIR TRACK NUMBER 4 WAS CORRODED AT FLANGE, STA 857 THRU 965. NEW TRACK INSTALLED PER SPM 6-70-01. SPLICE PER SRM 53-05, FIG 4F SHEET 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING OP 16 MAINT CHECK, CHAIR TRACK NUMBER 4 WAS CORRODED AT FLANGE, STA 857 THRU 965. NEW TRACK INSTALLED PER SPM 6-70-01. SPLICE PER SRM 53-05, FIG 4F SHEET 1.