What was found
DURING OP 16 MAINT CHECK, FOUND LIGHT CORROSION ON UPPER FLANGE OF FLOOR ATTACH ANGLES, STA 160 TO 200, BL 0 INCHES. REPLACED FLOOR SUPPORT PER SPM 6-70-01, PAGE 3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING OP 16 MAINT CHECK, FOUND LIGHT CORROSION ON UPPER FLANGE OF FLOOR ATTACH ANGLES, STA 160 TO 200, BL 0 INCHES. REPLACED FLOOR SUPPORT PER SPM 6-70-01, PAGE 3.