What was found
DURING OP 16 MAINT CHECK, CENTER FRAME ANGLE 5912350-17 WAS CRACKED APPROX 1.75 INCHES IN RADIUS AND 1.5 IN AT ATTACH RIVETS AT I/B END, STA 83.55, X=-10 IN, Z=42, RT SIDE. REPLACED ANGLE PER SRO 9530268 DRAWING AND EMLR 70039.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING OP 16 MAINT CHECK, CENTER FRAME ANGLE 5912350-17 WAS CRACKED APPROX 1.75 INCHES IN RADIUS AND 1.5 IN AT ATTACH RIVETS AT I/B END, STA 83.55, X=-10 IN, Z=42, RT SIDE. REPLACED ANGLE PER SRO 9530268 DRAWING AND EMLR 70039.