What was found
DURING OP 16 MAINT CHECK, FOUND CORRODED FORMER TIE AT STA 200, FORMER TO LONGERON 18R. INSTALLED NEW FORMER TIE FITTING AT STA 200 PER SPM 6-70-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING OP 16 MAINT CHECK, FOUND CORRODED FORMER TIE AT STA 200, FORMER TO LONGERON 18R. INSTALLED NEW FORMER TIE FITTING AT STA 200 PER SPM 6-70-01.