What was found
DURING CHECK-C MAINT, THE FUSELAGE TO VERTICAL STAB ATTACH ANGLE WAS CRACKED .875 INCH LONG AT RT SIDE, STA 1121. CRACK IS BEYOND STOP DRILLED HOLES OF LOWER LEG CRACK. REPAIRED PER SRM 53-05, FIG 230. DOUBLER INSTALLED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING CHECK-C MAINT, THE FUSELAGE TO VERTICAL STAB ATTACH ANGLE WAS CRACKED .875 INCH LONG AT RT SIDE, STA 1121. CRACK IS BEYOND STOP DRILLED HOLES OF LOWER LEG CRACK. REPAIRED PER SRM 53-05, FIG 230. DOUBLER INSTALLED.