What was found
DURING OP 16 MAINT CHECK,THE CABIN FLOOR AT STA 160 TO 200 HAD HEAVY CORROSION ON FLOOR PANEL ATTACH ANGLE RBL 45 IN. REMOVED AND REPLACED SUPPORT PER SPM 6-70-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING OP 16 MAINT CHECK,THE CABIN FLOOR AT STA 160 TO 200 HAD HEAVY CORROSION ON FLOOR PANEL ATTACH ANGLE RBL 45 IN. REMOVED AND REPLACED SUPPORT PER SPM 6-70-01.