What was found
DURING DAILY CHECK, FOUND EGRESS LIGHTS LEFT SIDE 'E' ZONE ENTIRE COLUMN INOP. REPAIRED CHAFED WIRE AND REPLACED BATTERY PACK. OPS CHECK PER MM 33-51-00. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING DAILY CHECK, FOUND EGRESS LIGHTS LEFT SIDE 'E' ZONE ENTIRE COLUMN INOP. REPAIRED CHAFED WIRE AND REPLACED BATTERY PACK. OPS CHECK PER MM 33-51-00. (M)