What was found
DURING DAILY CHECK, FOUND A-ZONE LEFT FLOOR EVAC LIGHTS DIM. FOUND LIGHT STRIP AT FAULT. REMOVED AND REPLACED LIGHT STRIP AT STAIRCASE. SYSTEM OPS CHECKED NORMAL AS PER MM 33-51-00 PG 501. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING DAILY CHECK, FOUND A-ZONE LEFT FLOOR EVAC LIGHTS DIM. FOUND LIGHT STRIP AT FAULT. REMOVED AND REPLACED LIGHT STRIP AT STAIRCASE. SYSTEM OPS CHECKED NORMAL AS PER MM 33-51-00 PG 501. (M)