What was found
FROM NON-ROUTINE ITEM, EVAC EXIT LIGHTS OUT ON U/D STAIRS/LAV AND CREW U/D EMER EXIT DOOR. REPLACED CREW BATTERY PACK, OPS CHECK OK PER MM 33-50-00. RECONNECTED BROKEN WIRE FOR U/D STAIRS/LAV. OPS CHECK OK PER 33-50-00. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.