What was found
DURING DAILY INSPECTION, FOUND UPPER DECK FLOOR MOUNTED EGRESS LIGHTS INOP, WIRES EXPOSED. SECURED FLOOR MOUNTED EGRESS LIGHTS AND REPAIRED WIRES. OPS CHECK NORMAL PER MM 33-51-00 PAGE 501. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING DAILY INSPECTION, FOUND UPPER DECK FLOOR MOUNTED EGRESS LIGHTS INOP, WIRES EXPOSED. SECURED FLOOR MOUNTED EGRESS LIGHTS AND REPAIRED WIRES. OPS CHECK NORMAL PER MM 33-51-00 PAGE 501. (M)