As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FOUND DURING DAILY CHECK, UPPER DECK CREW SERVICE DOOR SILL LIGHTS ARE INOP. FOUND BATTERY UNIT NOT CHARGING. REMOVED AND REPLACED BATTERY UNIT AND CHARGER. OPS CHECKS OK. EMERGENCY LIGHT AT SEAT 16HJK INOP. FOUND BROKEN WIRES, SPLICED WIRES. OPS CHECK OK. (M)