What was found
FLT 92 - SJU-MIA - ON CLIMB, NR 1 ENGINE FIRE SWITCH ILLUMINATED AND FIRE BELLSOUNDED. ENGINE SHUT DOWN. WHEN START LEVER WAS CUT OFF THE FIRE SWITCH LIGHT STOPPED ILLUMINATION. NACELLE TEMP DROPPED. FIRE BOTTLE WAS NOT DISCHARGED. AIR TURN BACK TO SJU. FOUND DUCT CLAMP CONNECTING 14TH STAGE MANIFOLD OFF, SECURED CLAMP. INSPECTION ENGINE INLET AND EXHAUST AREA. ENGINE REVERSER COWLING AND ASSOCIATED WIRING. NO DAMAGE FOUND. INSPECTED OIL SCREEN, FOUND OK ACCOMPLISHED HI POWER RUN. OPS AND LEAK CHECK OK PER MM 71-00-00. (M)