What was found
NR 1 ENGINE FIRE WARNING MOMENTARILY INDICATED ON CLIMB-OUT FROM TLV, RETARDED THRUST LEVER TO IDLE BEFORE ANY ACTION TAKEN. LIGHT/HORN EXTINGUISHED, OTHER INDICATIONS NORMAL. 'A' LOOP DROPPED TO NORMAL. 'B' LOOP CONTINUED TO RUN ABOVE 'A' LOOP. FOUND PNEUMATIC LEAK AT HIGH STAGE VALVE CLAMP. RESET AND TIGHTENED CLAMPS. PERFORMED RUN UP AND LEAK CHECK PER MM 71-00-00, TESTS 1, 3 AND 4. NO LEAKS NOTED. OPS CHECK NORMAL. (M)