What was found
DURING 12Y MAINTENANCE CHECK, FOUND CABIN FLOOR PANEL 251GF WITH DELAMINATION AT AFT OTBD. EDGE. ACCOMPLISHED BONDED REPAIR PER A330 SRM 53-02-00-283-001 AND 53-02-00-300-010. REPAIR DIMENSIONS 6" X 3".
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING 12Y MAINTENANCE CHECK, FOUND CABIN FLOOR PANEL 251GF WITH DELAMINATION AT AFT OTBD. EDGE. ACCOMPLISHED BONDED REPAIR PER A330 SRM 53-02-00-283-001 AND 53-02-00-300-010. REPAIR DIMENSIONS 6" X 3".