As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING SCHEDULED A-CHECK AT HAECO (NE1Y345K), DURING INSPECTION & SERVICING OF THE APU, THE APU DOOR FIRE SENSOR FORWARD MOUNDING BRACKET WAS FOUND BROKE; REFERENCE HAECO NON-ROUTINE WO.4103802. A REPAIR WAS EMBODIED UNDER FVCI EO 24212-1 REV B.