SDR U5QA06027

Service difficulty report · Detector · Cndair CL6002B16

Difficulty date
December 22, 2010
Submitted
December 24, 2010
Operation
Air carrier
Aircraft
N895CC
Make and model
Cndair CL6002B16
Aircraft serial
5177
Aircraft time
6,402 hours, 3,198 cycles
Part
Detector
Condition
Out Of Position
Location
Bleed Air Sys
Stage of operation
CL
How discovered
O
Nature of condition
N
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

PILOT REPORTED ON CLIMBOUT, W/ANTI-ICE ON, RIGHT 14TH BLEED DUCT FAIL LIGHT ILLUMINATED. A LEVEL OFF WAS PERFORMED, CHECKLIST COMPLETED, AND THE LIGHT EXTINGUISHED WHEN POWER WAS REDUCED. CREW ELECTED TO RETURN TO BLOCK. MAINTENANCE PERFORMED GROUND CHECKS INDICATED CLOSE PROXIMITY OF VALVE TO BLEED AIR LEAK DETECTOR LOOP. REPOSITIONED 14TH STAGE BLEED AIR SHUTOFF AND REGULATING VALVE AND RE-CLAMPED. SECURED BLEED AIR LEAK DETECTOR LOOP. GROUND RUN AND LEAK CHECKED GOOD.