Service difficulty report · Detector · Bombdr BD1001A10

Difficulty date
May 14, 2025
Submitted
May 23, 2025
Operation
Air carrier
Aircraft
N356VJ
Make and model
Bombdr BD1001A10
Aircraft serial
20546
Aircraft time
7,831 hours, 3,927 cycles
Part
Detector
Condition
Faulted
Location
Zone 100
Stage of operation
CR
How discovered
O
Nature of condition
J
Precautionary procedure
B, A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

RED PACK LEAK CAS B3-007406 LEAK DETECTED IN DUCT RUNNING FROM THE LEFT FLOW CONTROL VALVE TO THE PACK INLET AND PRECOOLER CROSS VALVE. PERFORMED OPERATIONAL CHECK OF THE AC SYSTEM. NO LEAK DETECTS AND SYSTEM OPERATES NORMALLY. PERFORMED BLEED LEAK DETECTION SYSTEM TROUBLESHOOTING. NOTED LEAK DETECTED 0005 AT 67% - FS 0791 PACK LOOP A. PERFORMED RESISTANCE CHECK OF MT141 AND MT73, FOUND MT73 RESISTANCE READ 4 OHMS HIGHER THAN NORMAL. REMOVED AND REPLACED MT73 PACK LOOP SENSOR WITH CUSTOMER SUPPLIED LOOP SENSOR. OPERATIONAL CHECKED GOOD. WORK DONE IAW BD100 AMM CHAPTER 36-21-11. (RTS 5/17)