What was found
ON CLIMB OUT PASSING 17000FT, SMOKE OBSERVED COMING OUT FROM BETWEEN FRAME OF LEFT WINDSHIELD AND LEFT SIDE WINDOW. MX C/A: RE-TORQUED THE LH WINDSHIELD TERMINALS T1 / T2 AND S2 TO PROPER TORQUE SPECS AS REQUIRED REF GVFD5000 AMM 56-10-01-400-801 STEP F(33). PERFORMED SATISFACTORY OPERATIONAL TESTING OF THE LH WINDSHIELD AND SIDE WINDOW ANTI-ICING SYSTEM REF GVFD5000 AMM 30-41-00-710-803.