What was found
FIRE LOOP 2 ENG R RIGHT ENGINE FIRE DETECTION SYSTEM LOOP 2 FAILURE. STATUS MSG01- ACTIVE CLIMB INTERMITTENT; FIRE LOOP 2 (RIGHT ENGINE) IS SHORTED. DB- ENGINE FIRE DETECTION CARD (RIGHT) MSG02- ACTIVE CLIMB HARD; ENGINE FIRE DETECTION CARD (RIGHT) HAS AN INTERNAL FAILURE. DB- ENGINE FIRE DETECTION CARD (RIGHT) MSG03- ACTIVE CLIMB HARD; ENGINE FIRE DETECTION CARD (RIGHT) HAS AN INTERNAL FAILURE. ITEM CNX PER PLF SHOWS NOT ACTIVE. MSG-2610232 ACTIVE CL INTER, MSG-2610012 ACTIVE CL HARD, MSG-2610012 ACTIVE CL HARD. FIRE LOOP FAILURE. REPLACED RIGHT ENGINE FIRE LOOP. FIRE TEST PASSED.