EMERGENCY EXIT LIGHTS ON IN FLT. RECYCLED SWITCH IN FLT. EMERGENCY LIGHTS STILL ON. REPLACED COCKPIT EMERGENCY LIGHT SWITCH 4WL. ALSO BATTERY PACK AND PWR SUPPLY UNIT 10WL (P/N 3214-54-10) AT DOOR 1L. SYSTEM OPS NORMAL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EMERGENCY EXIT LIGHTS ON IN FLT. RECYCLED SWITCH IN FLT. EMERGENCY LIGHTS STILL ON. REPLACED COCKPIT EMERGENCY LIGHT SWITCH 4WL. ALSO BATTERY PACK AND PWR SUPPLY UNIT 10WL (P/N 3214-54-10) AT DOOR 1L. SYSTEM OPS NORMAL.