What was found
EMERGENCY EXIT LIGHTS INOP. SEAT ROWS 45 THRU 53 LEFT, DOOR 4 LEFT FWD EXIT SIGN, DOOR 4 RIGHT AFT EXIT SIGN, LOWER WALL EMERGENCY LIGHT ACROSS DOOR 4 LEFT, AND DOOR 4 GALLEY AREA LOWER WALL EEL. THIS IS A REPETITIVE PROBLEM IN THIS SPECIFIC AREA ON 84XX AIRCRAFT COMING OUT OF INTERIOR MODIFICATION. REPLACED WATER SOAKED FEEDER CABLE AND TWO EMERGENCY WALL LIGHTS.