What was found
EQUIP COOLING EICAS AND OVERHEAD. REPLACED EQUIP COOLING INDICATION CIRCUIT BOARD. REMOVED AND CLEANED LOW FLOW SENSORS, HAVE HAD NO FAULTS FOR 1.5 HOURS AT ORD. EQUIP COOLING TEST OKAY.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EQUIP COOLING EICAS AND OVERHEAD. REPLACED EQUIP COOLING INDICATION CIRCUIT BOARD. REMOVED AND CLEANED LOW FLOW SENSORS, HAVE HAD NO FAULTS FOR 1.5 HOURS AT ORD. EQUIP COOLING TEST OKAY.