As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ELECTRONICS BAY, MAIN CABIN FLOORBEAM UPPER CHORD HAS EVIDENCE OF CRACK STARTING AT FASTENER'S HOLE, STA 325, RBL 11. MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGED SECTION OF FLOORBEAM T-CAP, RBL 11 TO RBL 25. INSTALLED NEW SECTION T-CAP AND ANGLE DOUBLER REPAIR.