What was found
DURING CABIN EMERGENCY LIGHTS CHECK, SYSTEM TEST FAILED WITH MESSAGE 'EPSU UNIT FWD L'. REPLACED FWD EPSU, NO HELP. FOUND SHORT FOR FLOOR LIGHTS AT SEAT 6 WHICH WAS TAKING OUT THE EPSU AT DOOR 1L. REPAIRED SHORT, GROUND CHECKED OKAY.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING CABIN EMERGENCY LIGHTS CHECK, SYSTEM TEST FAILED WITH MESSAGE 'EPSU UNIT FWD L'. REPLACED FWD EPSU, NO HELP. FOUND SHORT FOR FLOOR LIGHTS AT SEAT 6 WHICH WAS TAKING OUT THE EPSU AT DOOR 1L. REPAIRED SHORT, GROUND CHECKED OKAY.