What was found
EDP HYD OVHT LIGHT ILLUMINATED EICAS MSG (L,R) PRIM HYD OVHT DISPLAYED. PUMP WAS DEACTIVATED. POS 2 (01=L,02=R). CREW COMMENTS: R PRIM HYD PUMP OVHT SHUT OFF PUMP OVHT CAUTION EXTINGUISHED AFTER 12MIN 20SEC. SUPPLEMENTAL DATA UPDATE, FOUND NR 2 ENGINE (EDP) LEAKING HYD FLUID. REPLACED (EDP). OPS CHECKED RT HYD QUANTITY AND PRESSURE. OPS CHECKED GOOD AFTER ENG PUMP WAS REPLACED. REPLACED CASE DRAIN AND PRESSURE AND RETURN FILTERS, OPS GOOD.