Service difficulty report · Controller · Boeing 767322

Difficulty date
January 16, 2010
Submitted
January 22, 2010
Operation
Air carrier
Aircraft
N657UA
Make and model
Boeing 767322
Aircraft serial
27112
Aircraft time
73,412 hours, 11,881 cycles
Engine
Pwa PW4060
Part
Controller
Part number
11518661
Part serial
213
Condition
Faulty
Location
Cockpit Temp
Stage of operation
NR
How discovered
9
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FLT DECK TEMP CONTROL FAILED TO CONTROL DESIRED TEMP IN 'AUTO' OR 'MAN'. CREW COMMENTS: FLT DECK IS IN FULL HOT MANUAL & IT IS JUST BARELY COMFORTABLE. REPLACED FLIGHT COMPARTMENT TRIM MODULATING VALVE. DID NOT FIX PROBLEM. VALVE SHOWS FULL HOT, WITH COLD AIR COMING OUT OF GASPERS. REPLACED ZONE TEMP CONTROLLER AND TESTS OKAY.