As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
APU AUTO SHUTDOWN. APU INOP WILL NOT START FUEL CLUSTER MESSAGE. MSG 49-10440, APU MAINT PAGE FMV INDICATION DID NOT MOVE. METERING VALVE PART OF CLUSTER. REPLACED APUC, NO HELP. FOUND LARGE CHIPS ON LUBE SCAVENGE PUMP DETECTOR. THIS WILL BE AN APU CHANGE. REPLACED APU PER MM. OPS NORMAL.