What was found
DENT ON LEADING EDGE NR 2 SLAT APPROX 1 FT OUT FROM INBOARD EDGE MEASURES 6-32 DEEP. TEMPORARY REPAIR INSTALLED. MUST INSTALL STRUCTURAL INSERT REPAIR WITHIN 4500 FC, OR 6000 FH OR 20 MONTHS OR CHECK WHICHEVER OCCURS FIRST. REPLACED SLAT ON WUP K4341F.