What was found
AFT PIT BILGE, STR 43L CORRODED BETWEEN FR 58 AND 60. MAJOR REPAIR ACCOMPLISHED: CUTOUT DAMAGED STR AT FWD COUPLING AND AT AFT END AT FACTORY SPLICE. INSTALLED NEW COUPLINGS FWD AND AFT ENDS.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT PIT BILGE, STR 43L CORRODED BETWEEN FR 58 AND 60. MAJOR REPAIR ACCOMPLISHED: CUTOUT DAMAGED STR AT FWD COUPLING AND AT AFT END AT FACTORY SPLICE. INSTALLED NEW COUPLINGS FWD AND AFT ENDS.