What was found
EMERGENCY GENERATOR TEST FAILURE. REPLACED RELAY 30XE CHANGED FOR TROUBLESHOOTING. EMERGENCY GEN SYS STILL INOPERATIVE. AC ESS BUS CONTACTOR 15XE REPLACED FOR TROUBLESHOOTING EMERG GEN TEST FAILURE SYS STILL FAILS TEST. CONTACTOR WILL REQUIRE EMERG GEN TEST AND STATIC INVERTER TEST TO CLEAR DISCREPANCY IAW AMM. PERFORMED AN OPS TEST OF THE EMERGENCY GENERATING SYS FOR FAILED TEST. APPLIED T-S SOLUTIONS AS LISTED IN TSM TASK, WITH "AC ESS BUS FAULT" OR WITH "ESS TR FAULT". ACCOMPLISHED-OPS CHECKS GOOD.