What was found
NR 2 ENG SURGE, RTFL. ACCOMPLISHED POWER ASSURANCE CHECK. NO SURGING NOTICED. EPR 1.42, N2 88.4, EGT 580, FF 14.4 COOLED ENG, SHUTDOWN AND RESTART AND ACCOMPLISHED SAME CHECK WITH THE OTHER EEC, NO CHANGE. ACCOMPLISHED 14TH STAGE BLEED SYS TEST- FAILED TEST. NO INCREASE IN TEMP OCCURRED DURING TEST. ACCOMPLISHED BORESCOPE OF THE FRONT AND REAR OF THE HPC THROUGH AP-2 AND AP-8. NO LIMITING DEFECTS FOUND. OK TO CONTINUE IN SERVICE WITHOUT LIMITATIONS.