What was found
ON TAKE OFF BOTH BLEED DUCT PRESS INDICATORS FLUCTUATED. AFTER 5 MIN, BOTH STABILIZED WITH 10PSI SPLIT. ACCOMPLISHED PNEUMATIC HEALTH CHECK ON NR 1 AND 2 ENG PRSOV'S, BOTH FAILED HEALTH CHECK PER MM. REPLACED NR 1 ENG AND 2 ENG PRSOV.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.