What was found
APU QUIT WITH FAULT. NO START WITH FAULT LIGHT ON 2 RESTART ATTEMPTS. COMPLIED WITH MEL. REPLACED APU GENERATOR DUE TO MAG CHIP DETECTOR CONTAMINATION, GENERATOR SEIZED. ALSO RPL OIL FILTER ASSY. APU OPS NORMAL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
APU QUIT WITH FAULT. NO START WITH FAULT LIGHT ON 2 RESTART ATTEMPTS. COMPLIED WITH MEL. REPLACED APU GENERATOR DUE TO MAG CHIP DETECTOR CONTAMINATION, GENERATOR SEIZED. ALSO RPL OIL FILTER ASSY. APU OPS NORMAL.