What was found
"OPIC RA1" STATUS MSG ON EICAS. REPLACED RT OPBC, NO HELP. SWAPPED IN NEW OPIC CARD IN RA1 POSITION, NO HELP, RA2 POSITION, NO HELP. REINSTALLED ORIGINALS. SUSPECT RT OPIC CHASSIS M23217. REPLACED R OPCF M23217 IAW MM, NO HELP. TRIED KNOWN GOOD ENG ANTI ICE P5 PNL M33413 MESSAGE CLEARED AND OPIC TEST PASSED. REINSTALLED OLD PNL. REPLACED RT EAI SWITCH, ACCOMP MAT TEST IAW MM.