What was found
RIGHT ENGINE BLEED OFF LIGHT ON & RT ENG BLEED OFF EICAS MESSAGE, WITH ENG RUNNING, ENG BLEED SWITCH ON, LT & RT ISOLATION VALVES CLOSED, AC PACK SELECTED ON, & DUCT PSI IS ZERO. OFF LIGHT STAYS ON WHEN N1 IS ABOVE 41%. REPLACED PRSOV PER MM. ACP ENG RUN PER JRH ALL OPERATION AND INDICATIONS NORMAL.