As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLOORBEAM CORRODED ON UNDERSIDE, APPROX STA 1681, RBL 32. MAJOR REPAIR ACCOMPLISHED: MATERIAL REMAINING AFTER BLENDOUT EXCEEDS LIMITS OF SRM. TRIMMED OUT DAMAGED SECTION OF T-CAP AT BS 1681 FLOORBEAM FROM RBL 32 TO CUSP, FABRICATED 2 REPLACEMENT STRAPS AND ONE CLIP AND INSTALLED IAW SRM.