As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION ON FLOORBEAM AT STA 1660, RBL 0 -15, AND MATERIAL REMAINING AFTER CORROSION BLEND OUT EXCEEDS LIMITS OF SRM. MAJOR REPAIR ACCOMPLISHED: REMOVED DAMAGED AREA AT UPPER FLANGE AND FABRICATED AND INSTALLED ANGLE DOUBLERS AND STRAPS.