What was found
EMERGENCY LIGHTS SYS TEST FAILED. FAULT MSG EPSU INT LOAD EMER L, 33-51-38. FOUND CONNECTOR 7260VC10 DISCONNECTED AT STA. 2979 AT LT SIDEWALL & CONNECTOR COVER MISSING. SECURED CONNECTOR AND INSTALLED COVER. EMERGENCY LIGHTS OPS CHECKED USING SWITCH ON FLIGHT DECK, ACCOMPLISHED OPS TEST OF EMERGENCY LIGHTS, OPS CHECKED NORMAL, NO FAULTS.