Service difficulty report · Circuit Card · Boeing 777222

Difficulty date
December 26, 2010
Submitted
December 30, 2010
Operation
Air carrier
Aircraft
N795UA
Make and model
Boeing 777222
Aircraft serial
26927
Aircraft time
58,275 hours, 8,448 cycles
Engine
Pwa PW4090
Part
Circuit Card
Part number
285W0037101
Part serial
D00588
Condition
Failed
Location
Fire Detection
Stage of operation
NR
How discovered
O
Nature of condition
N
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

RT ENGINE FIRE-OVERHEAT DETECTION CARD FAULT OR FAILURE, OR AIMS LOSS OF ARINC 629 OR 429 COMMUNICATION WITH CARD. STATUS MSG01- ACTIVE CRUISE HARD; ENGINE FIRE DETECTION CARD (RT) HAS NO OUTPUT ON EFDC 429 BUS. SIGNAL GATEWAY (LT), RSCF MSG-2618892 ACTIVE ER HARD. REPLACE CARD FROM ANOTHER ACFT, FIRE SYS BACK TO NORMAL. (POWER SUPPLY LINEAR MONITOR UNIT).