LEFT ELEC HYD PUMP AUTO FUNCTION INOP. PUMP OPERATES NORMAL WHEN SELECTED ON. DEFERED. REPLACED ACMP PRESSURE SWITCH IAW MM. RUN ENGINE TO CONFIRM OPS OF AUTO FUNCTION, NO HELP. REPLACED K130 RELAY. OPS NORMAL.