As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FOUND P33 PANEL EQUIPMENT SHELF STANDOFFS BROKEN. OPENED P33 PANEL REMOVED INSIDE RELAY BRACKET, REMOVED 2 UPPER BROKEN STAND OFFS STARTED TO FABRICATE LOWER CORNER STRAP REPAIR. NO ELECTRICAL COMPONENTS WERE DISTURBED INSIDE P-33 PANEL. ALSO REPLACED BROKEN STAND-OFFS. CLEANED AREA AND CLOSED PANEL.