What was found
RAN OUT OF WATER 9 HRS INTO FLIGHT. QTY WAS FULL BEFORE DEPARTURE. SERVICED WATER TO 95 PERCENT FULL THEN CHECK. NO LEAK FOUND ON GROUND. WATER SOV SWITCH OFF AND M41, 42 COFFEEMAKER DEACTIVATED. DEFER IAW MEL. REPLACED PACKING. OPS CHECKED OK. NO LEAK FOUND. REACTIVATED CMS AND WATER SHUTOFF VALVE OPENED.