What was found
STALL WARNING OPS CHECK FAILS STEP B8, ALL OTHER STEPS CHECK OKAY. CAPT'S SIDE DOES NOT DISPLAY PITCH LIMIT INDICATOR AND NO STICK SHAKER WITH AIR DATA SWITCH IN ALT. FOUND 115V AC ON PIN 5 WITH SOURCE SWITCH IN ALT. FOUND 115V AC AT PIN 6 WITH SOURCE SWITCH IN NORMAL. MEASURED AT CONNECTOR D3925. SWAPPED STALL WARNING COMPUTERS, NO HELP. RETURNED TO ORIGINAL POSITIONS PER MM. REPLACED AIR DATA SOURCE SWITCH MASTER MODULE PER MM.